Production & Quality
12 görüntüleme
Poor EMA fatigue resistance
Sorun Belirtisi
EMA product fatigue life <10⁴ cycles, below the 10⁵ cycles requirement
Neden Analizi
EMA elastic recovery insufficient, accumulating plastic deformation each cycle; crosslinking degree too low with fast fatigue crack growth
Çözüm
1) Increase crosslinking degree to improve recovery and reduce accumulated deformation; 2) Select high molecular weight grade to raise fatigue threshold; 3) Product design reduces stress concentration
Temel Çıkarım
Poor fatigue resistance is caused by insufficient recovery and fast crack growth; increasing crosslinking is key
Bu faydalı oldu mu?
0 kişi bunu faydalı buldu