Material Analysis 12 görüntüleme

EMA processing temperature fluctuation

Sorun Belirtisi
Temperature fluctuates ±5-8°C during EMA processing, exceeding ±2°C control precision
Neden Analizi
Improper PID parameters of temperature control system; aging heater bands with uneven power; improper thermocouple position causing measurement deviation
Çözüm
1) Re-tune PID parameters; 2) Replace aging heater bands; 3) Adjust thermocouple position to the melt pool center
Temel Çıkarım
Temperature fluctuation is caused by improper temperature control system; PID tuning and heater band replacement are key