Material Analysis 9 views

EMA processing temperature fluctuation

Problem Phenomenon
Temperature fluctuates ±5-8°C during EMA processing, exceeding ±2°C control precision
Cause Analysis
Improper PID parameters of temperature control system; aging heater bands with uneven power; improper thermocouple position causing measurement deviation
Solution
1) Re-tune PID parameters; 2) Replace aging heater bands; 3) Adjust thermocouple position to the melt pool center
Key Takeaway
Temperature fluctuation is caused by improper temperature control system; PID tuning and heater band replacement are key
EMA temperature fluctuation PID tuning heater band thermocouple