Molds & Tooling
5 görüntüleme
Poor EVOH Fatigue Resistance
Sorun Belirtisi
EVOH product fatigue life <10⁴ cycles, below the 10⁵ cycles requirement
Neden Analizi
EVOH elastic recovery insufficient, plastic deformation accumulates each cycle; crosslinking degree too low, fatigue cracks propagate fast
Çözüm
1) Increase crosslinking degree to improve recovery and reduce accumulated deformation; 2) Select high molecular weight grade to raise fatigue threshold; 3) Product design to reduce stress concentration
Temel Çıkarım
Poor fatigue resistance is caused by insufficient recovery and fast crack propagation; increasing crosslinking is key