Molds & Tooling 5 görüntüleme

Mold temperature fluctuation causes product dimension and appearance fluctuation

Sorun Belirtisi
Mold temperature fluctuation causes product dimension and appearance fluctuation
Neden Analizi
Mold temperature controller heating power insufficient, unable to reach 40-80°C Mold temperature controller cooling capacity insufficient, low cooling efficiency Mold temperature sensor position improper, measurement deviation Mold temperature pipeline blocked, insufficient flow Large mold temperature differences between cavities in multi-cavity molds
Çözüm
Select a mold temperature controller with matched power Ensure the mold temperature controller has sufficient cooling capacity Correctly place the mold temperature sensor Clean mold temperature pipelines to ensure flow Ensure uniform temperature of each cavity in multi-cavity molds
Temel Çıkarım
The mold temperature system needs matched power and unobstructed pipelines