Molds & Tooling 5 görüntüleme

Twisting Deformation of CMC Products

Sorun Belirtisi
CMC products twist 2-3°/100mm along the axis
Neden Analizi
Asymmetric cooling causes shrinkage differences on each face, producing twisting torque; gate position produces asymmetric flow orientation
Çözüm
1)Symmetric cooling design to ensure uniformity of each face; 2)Symmetric gate arrangement; 3)Annealing to release twisting stress
Temel Çıkarım
Twisting deformation is caused by asymmetric cooling; symmetric cooling is the key
CMCtwisting deformationsymmetric coolinggate arrangementannealing