Molds & Tooling 7 görüntüleme

POE product twist deformation

Sorun Belirtisi
POE product twists 2-3°/100mm along the axis
Neden Analizi
Asymmetric cooling causes shrinkage difference of each face, producing twisting moment; gate position produces asymmetric flow orientation
Çözüm
1) Symmetric cooling design to ensure uniformity of each face; 2) Gates symmetrically arranged; 3) Annealing to release twisting stress
Temel Çıkarım
Twist deformation is caused by asymmetric cooling; symmetric cooling is key