Molds & Tooling 5 görüntüleme

Corrosion Problem During Processing of PBT Flame-Retardant Material

Sorun Belirtisi
Halogen-containing flame-retardant PBT corrodes molds and equipment during processing.
Neden Analizi
The halogen flame retardant partially decomposes at high temperature to produce acidic gases (HBr, etc.), which are corrosive to mold steel.
Çözüm
Use corrosion-resistant mold steel or stainless steel molds; clean the mold in time after processing; use a halogen-free flame retardant system.
Temel Çıkarım
PBT flame-retardant material corrosion requires equipment and mold protection.