Injection Molding
12 görüntüleme
Wear Particles from PBT '2079851475616104452 Equipment Mixed into Products
Sorun Belirtisi
Metal particles (iron, copper, etc.) are detected in the product.
Neden Analizi
Metal particles produced by the wear of the screw, barrel, and non-return ring are mixed into the melt and are not effectively filtered.
Çözüm
Use a magnetic frame or metal separator; regularly check equipment wear; replace worn parts.
Temel Çıkarım
PBT metal particles are a serious defect for electrical insulation.