Injection Molding
14 visualizações
Wear Particles from PBT '2079851475616104452 Equipment Mixed into Products
Fenómeno do problema
Metal particles (iron, copper, etc.) are detected in the product.
Análise das causas
Metal particles produced by the wear of the screw, barrel, and non-return ring are mixed into the melt and are not effectively filtered.
Solução
Use a magnetic frame or metal separator; regularly check equipment wear; replace worn parts.
Conclusão principal
PBT metal particles are a serious defect for electrical insulation.
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!