Blow Molding 5 görüntüleme

Uneven core rod temperature in PET bottle injection-stretch-'2079851475616104457

Sorun Belirtisi
When the PET preform is heated and stretched on the core rod, the core rod temperature distribution is uneven, causing local overheating or overcooling of the preform.
Neden Analizi
Some core rod heating elements fail or power distribution is uneven; the temperature control system responds with lag; scale on the core rod surface affects heat transfer.
Çözüm
Check and replace heating elements; optimize temperature control parameters; regularly clean the core rod surface; use infrared thermometry to verify temperature distribution.
Temel Çıkarım
PET core rod temperature uniformity is critical to preform stretching consistency.
PETcore roduneven temperatureheating elementinfrared thermometry