Molds & Tooling 6 مشاهدة

LCP Product Gate Design

ظاهرة المشكلة
Gate position determines success or failure.
تحليل الأسباب
Gate position determines LCP molecular orientation direction, directly affecting strength, thermal expansion, and warpage; a wrong gate position cannot be compensated by machine adjustment.; during on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience
الحل
①Mold flow analysis at the gate design stage; ②align orientation direction with the main stress direction; ③keep weld lines away from stressed areas; ④compare and verify multiple schemes.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
الخلاصة الأساسية
LCP gate design is the first decision in mold success or failure; orientation planning must precede manufacturing.; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
LCP;gate;design;orientation;mold flow;stress