Molds & Tooling 6 مشاهدة

POM Drool Contamination

ظاهرة المشكلة
Oxidized streaks appear on POM part surfaces
تحليل الأسباب
Nozzle drool oxidizes and is carried into the cavity in the next shot, forming streaks; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience; this mechanism has been repeatedly verified by industry literature and should be confirmed first during troubleshooting
الحل
Suck-back; valve gate nozzle; promptly clean drooled material; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
الخلاصة الأساسية
Drooled material must be cleaned immediately to prevent mixing into parts; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems