Molds & Tooling
6 مشاهدة
LCP mold temperature zone control
ظاهرة المشكلة
A certain performance or dimension of the LCP precision part does not meet customer specifications.
تحليل الأسباب
Mold design and process design failed to fully consider the anisotropy and ultra-high temperature characteristics of LCP.
الحل
Comprehensively improve the LCP processing quality system from multiple dimensions such as material, equipment, mold, and operation.
الخلاصة الأساسية
LCP precision processing requires the utmost coordination of process, equipment, and mold.
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا