Injection Molding
6 مشاهدة
Excessively long PET preform injection cycle
ظاهرة المشكلة
The PET preform '2079851475616104452 cycle is too long (>25 seconds), and production efficiency is low.
تحليل الأسباب
Cooling time is too long (PET crystallization exotherm causes slow cooling); mold cooling efficiency is insufficient; preform walls are too thick.
الحل
Optimize cooling water channels to increase cooling efficiency; appropriately reduce mold temperature; thin the preform wall thickness; use rapid heating and cooling technology.
الخلاصة الأساسية
The PET preform molding cycle directly affects production costs.
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا
شكرًا لك على ملاحظاتك!