Material Analysis 10 Aufrufe

EEA Strong Processing Odor

Problembeschreibung
Obvious pungent odor in the EEA processing workshop
Ursachenanalyse
EEA releases odorous volatiles at processing temperature (such as acetic acid, formaldehyde, etc.); additives decompose and release odor
Lösung
1) Control processing temperature within the EEA recommended range to reduce decomposition; 2) Strengthen workshop ventilation and exhaust; 3) Add absorbent to neutralize odor
Wichtigste Erkenntnis
Strong odor is caused by EEA decomposition and volatilization; temperature control and ventilation are key
EEA processing odor volatiles ventilation and exhaust temperature control