Material Analysis
14 visualizações
EEA Strong Processing Odor
Fenómeno do problema
Obvious pungent odor in the EEA processing workshop
Análise das causas
EEA releases odorous volatiles at processing temperature (such as acetic acid, formaldehyde, etc.); additives decompose and release odor
Solução
1) Control processing temperature within the EEA recommended range to reduce decomposition; 2) Strengthen workshop ventilation and exhaust; 3) Add absorbent to neutralize odor
Conclusão principal
Strong odor is caused by EEA decomposition and volatilization; temperature control and ventilation are key
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!