Material Analysis
10 Aufrufe
MP large processing odor
Problembeschreibung
MP processing workshop has an obvious pungent odor
Ursachenanalyse
MP releases odorous volatiles (such as acetic acid, formaldehyde, etc.) at processing temperature; additives decompose releasing odor
Lösung
1) control processing temperature within the MP recommended range to reduce decomposition; 2) strengthen workshop ventilation; 3) add absorbent to neutralize the odor
Wichtigste Erkenntnis
large odor is caused by MP decomposition volatilization; temperature control and ventilation are key