Material Analysis 12 görüntüleme

MP large processing odor

Sorun Belirtisi
MP processing workshop has an obvious pungent odor
Neden Analizi
MP releases odorous volatiles (such as acetic acid, formaldehyde, etc.) at processing temperature; additives decompose releasing odor
Çözüm
1) control processing temperature within the MP recommended range to reduce decomposition; 2) strengthen workshop ventilation; 3) add absorbent to neutralize the odor
Temel Çıkarım
large odor is caused by MP decomposition volatilization; temperature control and ventilation are key