Molding Process 6 Aufrufe

LCP thin-wall long-flow filling

Problembeschreibung
LCP thin-wall (<0.3mm) micro parts are insufficiently filled.
Ursachenanalyse
Although LCP has extremely good flowability, it cools, solidifies and sets quickly during the process, especially in thin walls.
Lösung
Further increase melt temperature to 370-390°C; mold temperature >150°C; increase injection speed.
Wichtigste Erkenntnis
LCP thin-wall filling requires extremely high temperature.
LCPthin wallfillingmelt temperaturemold temperature