Material Drying 3 Aufrufe

LCP drying requirements

Problembeschreibung
Whether LCP needs drying and the drying conditions.
Ursachenanalyse
Although LCP has low hygroscopicity (<0.02%), trace moisture during 390°C processing may also trigger degradation.
Lösung
Recommend drying at 150°C/4h or follow supplier recommendations.
Wichtigste Erkenntnis
LCP drying is a cautious operation for high-temperature processing.