Material Drying 2 views

LCP drying requirements

Problem Phenomenon
Whether LCP needs drying and the drying conditions.
Cause Analysis
Although LCP has low hygroscopicity (<0.02%), trace moisture during 390°C processing may also trigger degradation.
Solution
Recommend drying at 150°C/4h or follow supplier recommendations.
Key Takeaway
LCP drying is a cautious operation for high-temperature processing.