Molding Process
6 Aufrufe
POE film puncture strength low
Problembeschreibung
POE film puncture <10N, below 15N
Ursachenanalyse
POE elastic modulus low, large deformation under puncture; thickness <0.05mm
Lösung
1) Thicken to 0.08-0.1mm; 2) 5-10wt% HDPE to increase modulus; 3) DCP 0.2wt% slight crosslinking
Wichtigste Erkenntnis
Low puncture is caused by low modulus and thin thickness; thickening and stiffening
War das hilfreich?
0 Personen fanden dies hilfreich