Problembeschreibung
The material decomposes during processing, producing odorous gas.
Ursachenanalyse
The processing temperature is too high >320°C; the carbonate bonds in PAR decompose to produce low molecules such as CO₂ and phenol.
Lösung
Strict temperature supervision not exceeding 320°C; minimize the barrel residence time; forced exhaust ventilation.
Wichtigste Erkenntnis
PAR decomposition gas needs environmental control.