Injection Molding
15 visualizaciones
Gas produced by decomposition during PAR '2079851475616104452
Fenómeno del problema
The material decomposes during processing, producing odorous gas.
Análisis de la causa
The processing temperature is too high >320°C; the carbonate bonds in PAR decompose to produce low molecules such as CO₂ and phenol.
Solución
Strict temperature supervision not exceeding 320°C; minimize the barrel residence time; forced exhaust ventilation.
Conclusión clave
PAR decomposition gas needs environmental control.