Injection Molding
14 visualizações
Gas produced by decomposition during PAR '2079851475616104452
Fenómeno do problema
The material decomposes during processing, producing odorous gas.
Análise das causas
The processing temperature is too high >320°C; the carbonate bonds in PAR decompose to produce low molecules such as CO₂ and phenol.
Solução
Strict temperature supervision not exceeding 320°C; minimize the barrel residence time; forced exhaust ventilation.
Conclusão principal
PAR decomposition gas needs environmental control.