Menü
Materialien Maschinen
Einblicke
Artikel Videos Problem & Lösung
About
Über Chembull Medienpartner
Kontaktieren Sie uns
Sprache
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Zurück zu Problem & Lösung
Extrusion & Post 3 Aufrufe

Dimensional changes of PET injection molded products at high temperature

Problembeschreibung
PET products show obvious dimensional changes in 80-100°C service environments, causing assembly failure.
Ursachenanalyse
Fast cooling during '2079851475616104452 makes crystallization incomplete; post-crystallization at high temperature causes volume shrinkage; annealing is insufficient and mold temperature is on the low side.
Lösung
Increase mold temperature to promote full crystallization; fully anneal at 130-140°C/1-2h; select PET grades with high crystallization rate.
Wichtigste Erkenntnis
The high-temperature dimensional stability of PET products depends on sufficient crystallinity.
PETdimensional changepost-crystallizationannealingmold temperature

War das hilfreich?

0 Personen fanden dies hilfreich

ChemAI