Molds & Tooling 4 visualizaciones

Internal microcracks in the product

Fenómeno del problema
Microcracks invisible to the naked eye appear inside the product. When this defect occurs in products of Process No. 2, it is usually related to a specific process parameter range or equipment status. If it persists, it will directly affect the product qualification rate and production cycle, increasing material loss and rework costs. Timely diagnosis and elimination is a basic requirement to ensure stable production.
Análisis de la causa
1. Material factor: Reaction exotherm causes internal thermal stress, curing shrinkage stress concentration, low-temperature demolding produces cold shock cracks, and the formulation toughness is insufficient. 2. Mixing quality factor: In the RIM process, the mixing uniformity of the two components is the foundation of all quality; the Reynolds number of the mixing head, the impingement mixing energy, and the residence time distribution are the key engineering parameters that determine the mixing quality. 3. Temperature control factor: The raw material temperature affects the component viscosity and reaction rate, and the mold temperature affects the curing process and product surface quality; both need to be precisely controlled within a narrow window.
Solución
1. Process parameter optimization and adjustment: Control the reaction exotherm, optimize the curing program, increase the demolding temperature, and add chain extenders to improve toughness. 2. Systematic troubleshooting method: RIM problem troubleshooting follows the order of "formulation -> mixing -> temperature control -> equipment". First check the two-component ratio and catalyst dosage, then check the mixing head and self-cleaning function, next troubleshoot the raw material and mold temperature control, and finally check the accuracy of the metering pump and hydraulic system. 3. Preventive management: Establish standardized process parameter cards and quality control limits for each mold/product, and regularly conduct process capability index (CPK) assessments. For recurring problems, use fishbone diagrams or 5Why analysis to trace the root cause, and solidify countermeasures as PFMEA control points.
Conclusión clave
This problem is a typical manifestation of internal microcracks in the product in the RIM process, and the core of the solution lies in ensuring the precise ratio and sufficient mixing of the two components, while controlling the reaction temperature and curing conditions within the optimal window. It is recommended to start troubleshooting from the mixing system and metering accuracy.
shrinkage rate wall thickness design cooling water circuit holding pressure dimensional accuracy