Molds & Tooling
4 visualizaciones
Cold Material Blockage in Runners
Fenómeno del problema
The cold material that entered the runner earlier blocks the runner.
When this defect occurs in products of Process No.
4, it is usually related to a specific process parameter range or equipment status.
If it persists, it will directly affect the product qualification rate and production cycle, increasing material loss and rework costs.
Timely diagnosis and elimination is a basic requirement for ensuring stable production.
Análisis de la causa
1.
Mold design factors: transfer started before the runner temperature reached the set value, material cooling and hardening in the runner, no cold slug well in the runner, and insufficient mold preheating.
2.
Feeding factors: The volume of the loading chamber, the loading amount, and the preheating state of the material directly determine the transfer pressure and filling effect, and are key variables unique to transfer molding.
Solución
1.
Process parameter optimization and adjustment: Ensure the runners are fully preheated, add cold slug wells, and transfer only after the mold is preheated to the process temperature.
2.
Systematic troubleshooting method: Troubleshooting of transfer molding problems follows the order of "runner -> feeding -> parameters -> mold".
First check whether the runners and gates are blocked or worn, then verify the loading amount and material preheating, then adjust the transfer pressure and speed, and finally check the mold venting and temperature uniformity.
3.
Preventive management: Establish standardized process parameter cards and quality control limits for each mold/product, and regularly conduct process capability index (CPK) evaluations.
For recurring problems, use fishbone diagrams or 5Why analysis to trace the root cause, and solidify countermeasures as PFMEA control points.
Conclusión clave
This problem is a typical manifestation of cold material blockage in runners in transfer molding.
The core of the solution lies in the reasonable design of the runner and gate system, the effective transmission of transfer pressure, and the uniform control of mold temperature.
It is recommended to start troubleshooting from the runner system and transfer parameters.
¿Le ha resultado útil?
0 personas encontraron esto útil
¡Gracias por sus comentarios!