Molds & Tooling
8 visualizaciones
LCP Mold Temperature Selection
Fenómeno del problema
Mold temperature setting affects product performance and appearance.
Análisis de la causa
LCP mold temperature of 80~120℃ is sufficient, lower than PPA or PEEK; mold temperature affects crystallization speed and surface quality, and water-heated molds are usually adequate.
Solución
①Set mold temperature at 80~120℃; ②water-heated molds are sufficient; ③stabilize mold temperature fluctuation; ④fine-tune according to surface requirements.; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Conclusión clave
LCP mold temperature demand is relatively mild; water-cooled molds suffice in the 80~120℃ range, which is its equipment-friendly side.; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
¿Le ha resultado útil?
0 personas encontraron esto útil