Extrusion & Post
2 visualizaciones
LDPE Film Corona Decay
Fenómeno del problema
After storage for a period of time, the treated film's printing adhesion decreases.
Análisis de la causa
The corona treatment effect naturally decays with storage time; slip agent migrating to the surface also reduces surface energy.; During on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience.
Solución
①Re-test the dyne value before printing and re-treat online when necessary; ②Control the slip agent addition amount; ③Shorten storage time after treatment; ④Standardize storage conditions.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability.
Conclusión clave
Corona aging is a common-sense problem in film processing; treating right before use or re-treating online is a safe practice.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence
¿Le ha resultado útil?
0 personas encontraron esto útil