Molds & Tooling 11 visualizaciones

PA12 Product Gate Design

Fenómeno del problema
Gate area defects.
Análisis de la causa
Gate form and position affect filling; PA12 has good flowability and the gate must be fine.; During on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience
Solución
①Optimize form and position; ②control shear; ③appropriate size; ④avoid stress-bearing area.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability; Change only one variable at a time and record parameter changes to facilitate locating effective measures
Conclusión clave
Gate design affects filling quality.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; Include this case in the defect archive as a troubleshooting reference for subsequent similar problems