Menú
Materiales Maquinaria
Perspectivas
Artículos Vídeos Problema y solución
About
Acerca de Chembull Socios de medios
Contáctenos
Idioma
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Volver a Problema y solución
Extrusion & Post 10 visualizaciones

PMMA Extrusion Temperature 180-250℃

Fenómeno del problema
Extruded sheets have many surface defects, and molecular weight distribution changes cause performance fluctuations
Análisis de la causa
PMMA extrusion temperature 180-250℃; sheet and profile formulations use higher molecular weight grades; a 3:1 compression ratio metering screw is recommended, and a vented screw with L/D ratio 20-30 is best
Solución
①Extrusion temperature 180-250℃ adjusted by grade; ②select a 3:1 compression ratio metering screw; ③high-requirement lines use L/D 20-30 vented screws
Conclusión clave
PMMA extrusion equipment selection has clear specifications; screw parameter matching is the hardware basis for stable sheet quality; After confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence.
PMMA; extrusion; 180-250℃; screw; venting

¿Le ha resultado útil?

0 personas encontraron esto útil

ChemAI