Molding Process 15 visualizaciones

POM spray pump valve parts

Fenómeno del problema
The fitting accuracy of internal POM parts of the spray pump decreases, the spray volume is inaccurate, and the spring seat breaks
Análisis de la causa
Pump valve parts require dimensional precision and chemical resistance; long-term contact with the content solvent superimposed with cyclic load initiates cracks at stress concentration points; dimensional drift changes the fitting clearance
Solución
①Perform immersion verification of content compatibility; ②round and strengthen load-bearing parts such as spring seats; ③accept dimensions in the stabilized state after annealing; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
Conclusión clave
POM pump valve parts are a combined test of precision plus chemical resistance; compatibility verification and structural reinforcement go in parallel, and dimensional acceptance looks at the stabilized state; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
POM;spray pump;valve part;chemical resistance;precision