Molds & Tooling 8 visualizaciones

EEA Internal Shrinkage Voids

Fenómeno del problema
Shrinkage voids of 0.5-2mm diameter in the center of EEA thick-wall products
Análisis de la causa
After cooling of the thick-wall area, the interior shrinks but the surface has solidified and cannot be fed; insufficient holding time, gate freezes too early
Solución
1) Extend holding time until the gate is completely frozen; 2) Increase gate size to delay freezing; 3) Product design to reduce wall thickness differences
Conclusión clave
Shrinkage voids are caused by thick-wall shrinkage and insufficient holding; extending holding is key