Injection Molding 2 visualizaciones

Glass Fibre periodic surface waviness

Fenómeno del problema
Glass Fibre product surface has periodic waviness with spacing 5-15mm
Análisis de la causa
injection speed fluctuates periodically; hydraulic system unstable; screw rotation speed unstable
Solución
1) overhaul injection system to stabilize pressure and speed; 2) replace hydraulic drive with servo motor drive; 3) PID control to stabilize injection parameters
Conclusión clave
waviness is caused by unstable injection; equipment overhaul and PID control are key