Molding Process 4 visualizaciones

MP poor antistatic effect

Fenómeno del problema
MP product surface resistance >10¹²Ω, severe static electricity
Análisis de la causa
antistatic agent addition insufficient <0.1wt%; antistatic agent migration rate slow, not reaching the surface
Solución
1) increase antistatic agent to 0.3-0.5wt%; 2) select an antistatic agent with fast migration rate; 3) coat the surface with antistatic liquid for immediate effect
Conclusión clave
poor antistatic effect is caused by insufficient addition; increasing antistatic agent is key