Extrusion & Post
6 visualizaciones
Mold coating wear in PCTG '2079851475616104452
Fenómeno del problema
After long-term use, the mold coating peels off and loses its release effect.
Análisis de la causa
Insufficient bonding between coating and mold; wear and corrosion cause coating failure.
Solución
Use high-quality coatings (DLC); regularly re-coat; properly maintain the mold.
Conclusión clave
PCTG mold coating life affects production continuity.