Injection Molding
15 visualizaciones
Over-temperature risk of oil temperature machine in PCTG '2079851475616104452
Fenómeno del problema
Inaccurate temperature control of the oil temperature machine causes over-temperature.
Análisis de la causa
Oil temperature machine temperature measurement deviation, oil temperature out of control beyond the setting.
Solución
Use a water temperature machine or precisely controlled oil temperature machine; regularly calibrate temperature sensors.
Conclusión clave
PCTG mold temperature control equipment needs to be precise and reliable.
¿Le ha resultado útil?
0 personas encontraron esto útil