Injection Molding 2 views

Over-temperature risk of oil temperature machine in PCTG '2079851475616104452

Problem Phenomenon
Inaccurate temperature control of the oil temperature machine causes over-temperature.
Cause Analysis
Oil temperature machine temperature measurement deviation, oil temperature out of control beyond the setting.
Solution
Use a water temperature machine or precisely controlled oil temperature machine; regularly calibrate temperature sensors.
Key Takeaway
PCTG mold temperature control equipment needs to be precise and reliable.