Extrusion & Post
8 visualizaciones
Product dimensions out of tolerance
Fenómeno del problema
Key product dimensions exceed drawing tolerance requirements and cannot be assembled
Análisis de la causa
The predicted shrinkage rate value is inaccurate; mold temperature fluctuation causes shrinkage rate changes (each °C of mold temperature can affect shrinkage rate by 0.02-0.05%); holding pressure parameters are unstable
Solución
Correct mold cavity dimensions based on the actual shrinkage rate; stabilize mold temperature fluctuation within ±2°C; fix the holding pressure curve and cooling time
Conclusión clave
Dimensional accuracy depends entirely on the stability and predictability of shrinkage behavior
¿Le ha resultado útil?
0 personas encontraron esto útil
¡Gracias por sus comentarios!