Material Drying
4 조회수
Warpage deformation needs quantitative measurement and cause analysis
문제 현상
Warpage deformation needs quantitative measurement and cause analysis
원인 분석
Warpage measurement method not standardized, data inaccurate
Warpage direction inconsistent with the melt flow direction, analysis difficult
Warpage changes over time (changes after moisture absorption), PA type obvious
Warpage related to ambient temperature changes
Warpage data differs greatly under different measurement conditions (dry state/wet state)
해결 방법
Use CMM measurement or laser scanning to quantify warpage
Analyze the relationship between warpage direction and flow direction
PA type needs warpage measurement after conditioning
Control the measurement environment temperature
Mark the moisture content of the product at the time of measurement
핵심 요약
Warpage needs quantitative measurement and marking of moisture conditions
이 정보가 도움이 되었나요?
0 명이 도움이 되었다고 합니다
의견 주셔서 감사합니다!