Material Drying 3 Aufrufe

Warpage deformation needs quantitative measurement and cause analysis

Problembeschreibung
Warpage deformation needs quantitative measurement and cause analysis
Ursachenanalyse
Warpage measurement method not standardized, data inaccurate Warpage direction inconsistent with the melt flow direction, analysis difficult Warpage changes over time (changes after moisture absorption), PA type obvious Warpage related to ambient temperature changes Warpage data differs greatly under different measurement conditions (dry state/wet state)
Lösung
Use CMM measurement or laser scanning to quantify warpage Analyze the relationship between warpage direction and flow direction PA type needs warpage measurement after conditioning Control the measurement environment temperature Mark the moisture content of the product at the time of measurement
Wichtigste Erkenntnis
Warpage needs quantitative measurement and marking of moisture conditions