Material Drying
5 görüntüleme
Warpage deformation needs quantitative measurement and cause analysis
Sorun Belirtisi
Warpage deformation needs quantitative measurement and cause analysis
Neden Analizi
Warpage measurement method not standardized, data inaccurate
Warpage direction inconsistent with the melt flow direction, analysis difficult
Warpage changes over time (changes after moisture absorption), PA type obvious
Warpage related to ambient temperature changes
Warpage data differs greatly under different measurement conditions (dry state/wet state)
Çözüm
Use CMM measurement or laser scanning to quantify warpage
Analyze the relationship between warpage direction and flow direction
PA type needs warpage measurement after conditioning
Control the measurement environment temperature
Mark the moisture content of the product at the time of measurement
Temel Çıkarım
Warpage needs quantitative measurement and marking of moisture conditions
Bu faydalı oldu mu?
0 kişi bunu faydalı buldu
Geri bildiriminiz için teşekkürler!