Injection Molding 4 views

LLDPE injection molded product dimensional shrinkage

Problem Phenomenon
Dimensions undersized.
Cause Analysis
Large shrinkage + insufficient holding pressure.
Solution
①Increase holding pressure; ②actual measurement and mold correction; ③unify measurement timing.
Key Takeaway
Dimension = holding pressure + actual measurement.