Molds & Tooling
1 views
PC hot runner temperature
Problem Phenomenon
【Problem Phenomenon】PC hot runner gate defects, improper temperature control
Cause Analysis
Hot runner temperature matched with barrel 290-310℃; local overheating degrades, low temperature causes cold slug; sufficient preheating at startup;During on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based solely on experience
Solution
Hot runner 290-310℃ zoned closed loop; startup preheating; regular thermocouple inspection;After adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability;Change only one variable at a time and record parameter changes to facilitate locating effective measures
Key Takeaway
PC hot runner 290-310℃, preheating and temperature control both emphasized;After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence;Include this case in the defect archive as a reference for troubleshooting similar problems in the future
Was this helpful?
0 people found this helpful
Thank you for your feedback!