Molds & Tooling 4 görüntüleme

PC hot runner temperature

Sorun Belirtisi
【Problem Phenomenon】PC hot runner gate defects, improper temperature control
Neden Analizi
Hot runner temperature matched with barrel 290-310℃; local overheating degrades, low temperature causes cold slug; sufficient preheating at startup;During on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based solely on experience
Çözüm
Hot runner 290-310℃ zoned closed loop; startup preheating; regular thermocouple inspection;After adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability;Change only one variable at a time and record parameter changes to facilitate locating effective measures
Temel Çıkarım
PC hot runner 290-310℃, preheating and temperature control both emphasized;After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence;Include this case in the defect archive as a reference for troubleshooting similar problems in the future