Molds & Tooling 2 views

PPS product cooling management

Problem Phenomenon
High-temperature mold cooling challenges.
Cause Analysis
PPS mold temperature is high and cooling system design is special; oil temperature units or electric heating are commonly used.; During on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based solely on experience
Solution
①High-temperature mold temperature controller configuration; ②optimize water circuit temperature resistance; ③balance temperature; ④monitor stability.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Key Takeaway
PPS cooling system must withstand high temperature; mold temperature controller selection is the foundation.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
PPS; cooling; mold temperature controller; high temperature; water circuit; stability