Molds & Tooling 8 visualizaciones

PPS product cooling management

Fenómeno del problema
High-temperature mold cooling challenges.
Análisis de la causa
PPS mold temperature is high and cooling system design is special; oil temperature units or electric heating are commonly used.; During on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based solely on experience
Solución
①High-temperature mold temperature controller configuration; ②optimize water circuit temperature resistance; ③balance temperature; ④monitor stability.; After adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Conclusión clave
PPS cooling system must withstand high temperature; mold temperature controller selection is the foundation.; After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems