Clamping force directly affects product quality and mold safety

Problem Phenomenon
Clamping force directly affects product quality and mold safety
Cause Analysis
Insufficient clamping force produces flash Excessive clamping force, mold deformation or increased product internal stress Clamping force setting not calculated based on cellulose acetate butyrate injection pressure Clamping force fluctuates unstably Multi-cavity mold clamping force distribution uneven
Solution
Clamping force ≥ projected area × injection pressure × 1.1-1.2 safety factor Avoid excessive clamping force increasing internal stress Reasonably calculate based on cellulose acetate butyrate injection pressure Stabilize the clamping force system Ensure uniform force on multiple cavities
Key Takeaway
Clamping force needs to be calculated based on projected area and injection pressure